JTB Power Solution Kit - 50A Power From 30A Service!
This product has been discontinued.
JTB Power Solution Kit - 50A Power From 30A Service!
Description / JTB Power Solution Kit - 50A Power From 30A Service!
The JTB Power Solution configures the available power in a typical RV Park (30 AMP Main Circuit and 20 AMP circuit or GFCI auxiliary) for use in your RV automatically. Once the JTB Power Solution is installed you will simply plug your existing power cord into the 30 AMP service and plug the additional power cord (added to your RV with the JTB Power Solution install) into the 20 AMP circuit or GFCI. The JTB Power Solution is the only power management tool on the market that will allow you to put the full 50 AMPS of service available at a Typical RV Park 30 AMP Power Pole to work in your RV, regardless of whether the 20 AMP auxiliary outlet is a GFCI or not. Once installed, you will be able to run both AC units at the same time to keep your RV nice and cool or run your other appliances with your single AC unit simultaneously. The JTB Power Solution is a power management solution that allows you to use what is available now at the typical RV hook up (30 AMP main service with auxiliary 20 AMP circuit or GFCI) in your RV. The JTB Power Solution is automatic, so there are no switches or meters to monitor. Traditional cheater boxes no longer are an effective solution and will not work with your RV. Although they are commonly sold to solve this problem you will quickly determine that at the typical RV Park Power Pole, if a GFCI is present, your cheater box will cause the GFCI to fail every time, it’s just a matter of minutes when both AC units are running. The JTB Power Solution solves other power management problems too.
Put the JTB Power Solution to work in your RV today. Beating the heat utilizing both AC units or using other appliances while running your AC unit will be safe and hassle free and has never been easier.
The JTB Power Solution is ETL Tested and Certified and carries a one year warranty.
The JTB Power Solution was designed and is manufactured by fellow RV users to solve a well known power problem. “We welcome the opportunity to solve your RV Power Management problems! We live in Texas and simply cannot enjoy camping in the Texas HEAT without using both AC Units. RV Parks will not let you run generators so I created a solution to solve our problems. I think you will truly enjoy our product once you have installed it”…….”cheater boxes that are commonly pushed by RV accessory houses and accessory reseller simply fail when hooked up to a GFCI. It is so frustrating… Well Not any More- the JTB Power Solution has got you covered”
- Sincerely, Jack Hurst (master mind behind this unique break thru solution)
Could Your RV benefit from a JTB? If you answer yes, you need a JTB Power Solution!
Are you TRIPPING BREAKERS or not able to use both AC Units in your 30 or 50 AMP RV?
Are you TRIPPING BREAKERS for the 2nd AC UNIT in your 50 AMP RV while at a 30 AMP State Park?
Ladies, do you have problems blow drying your hair due to circuit overload or are you having to turn off other appliances to dry your hair?
Are you using a CHEATER BOX that will NOT WORK with a FAULT GROUND (GFCI) circuit (Standard in 30 AMP RV Parks)?
Are you wanting to ADD ANOTHER CIRCUIT for an AIR CONDITIONER, WASHER AND DRYER, MICROWAVE or another appliance?
Do you want to CONVERT YOUR 30 AMP RV TO A 50AMP?
Are you wanting to ADD 20 to 40 MORE AMPs to your RV?
Would you like to CONVERT your 50 AMP RV to a 90 AMP?
Are you using a MANUAL POWER MANAGEMENT SYSTEM that directs the power load for you RV from one appliance to the next?
Are you having POWER PROBLEMS with your RV?
Are you TRIPPING your AC BREAKER due to overload?
Are you TRIPPING BREAKERS when connected to RV PARK POWER POLES?
Are you REPLACING your POWER CORD due to EXCESSIVE HEAT?
Problems Solved! The JTB Power Solution will do all of the above and do it automatically:
Powers your 50 amp RV in a 30 amp state park by using the 20 amp GFCI receptacle.
Eliminates GFCI tripping at typical RV hook-ups--works with GFCI hook-ups in all RV parks.
Eliminates need for running generator to operate two air conditioners—prohibited in many parks.
Allows unlimited use of both air conditioners in all RVS---Travel Trailers, 5th Wheels and Motorhomes.
Allows use of one air conditioner and another appliance such as a microwave simultaneously.
Lets you use your hair dryer without blowing circuits in all 50 amp or 30 amp RVs.
More Information
Item # | 72233 |
---|---|
Model | 2010-100KIT |
Adapts | 30A main circuit + 20A circuit or GFCI auxiliary to 50A |
Features | Power Sources: 2-110 Volt AC Power Inputs Type of Power: Single Phase 50/60 Hz Electrical Rating: 20 AMP Type of Solution: Dual Transfer Switches Type of Switch: Automatic 40 AMP Relays Type of Enclosure: Type 1 UL Rated Type of Protection: Dual 20 AMP Breakers Type of Hookup: 30 ft.-- 30 Amp Power Cord with 20 Amp Adapter Type of Computer: Fixed Solid State Micro Chip Type of Circuit Board: 2-Sided Plated PCB .0625 Thick, Recognized FR4 Material, Copper Plating Type of Decals: 3 mil. Acrylic Based Pressure Sensitive Type of Certification: ETL Approved US UL Std. 1008 & Canada CSA Std. C22.2 No. 178.1 |
Included | JTB System Box with Install Kit |
Warranty | 1 Year |
Made in | USA |
Special Order Item | No |
UPC | 736211819680 |
LTL Freight | No |